CHAPTER 4 - Impedance Matching
162
Figure 4.2-17 Measuring power transfer when L-C resonator is present between source and load
Figure
4.2-18 Frequency response of L-C series resonator circuit
As is to be expected, maximum power transfer between source and load is achieved at the resonant
frequency (Figure 4.2-18).
Video 4.1 illustrates the concepts explained in section 4.2.1, 4.2.2 and 4.2.3 by means of
Microwave Office simulations.
ACVS
ID=V1
Mag=1 V
Ang=0 Deg
Offset=0 V
DCVal=0 V
RES
ID=RS
R=50 Ohm
CAP
ID=Cs
C=5.6 pF
IND
ID=Ls
L=4.5 nH
RES
ID=RL
R=50 Ohm
W
V
I
1 2
3
P_METER3
ID=P1
1 1001 2001 3000
Frequency (MHz)
Series_Power
0
0.5
1
1.5
2
2.5
3
|Pcomp(P_METER3.P1,1)| (mW)
LC_series_bandpass
Conquer Radio Frequency
162 www.cadence.com/go/awr