2.5 Reflection of DC voltage in Transmission lines 53 Figure 2.5-17 Current starts flowing back towards the generator Figure 2.5-18 Voltage travelling back towards generator Figure 2.5-19 Voltage travelling back towards generator Eventually the pulse travels back into the source and, since Z s = Z 0 ,is fully absorbed (Figure 2.5-20). -I E E/2 E/2 -I E/2 E E/2 E/2 E -I E/2 E/2 E/2 Conquer Radio Frequency 53 www.cadence.com/go/awr